The First Unit In A New Home
A room with no aircond needs its capacity worked out before anything is bought. We measure the floor area, count the glazing and note which wall takes the afternoon sun, then name the horsepower that suits it.
A new unit performs the way it was fitted. We size it to the room, run the pipe and the drain properly, and vacuum the system before the gas goes in.
You have bought the unit, or you are about to, and the shop has quoted a fitting price with the box. What that price covers is the part nobody explains until the room fails to cool two summers later.
An undersized unit runs without a break and still leaves the room warm. A drain laid flat backs water down the wall within months. Air left in the pipework turns into acid and takes the compressor with it. None of that shows on the day the unit is switched on.
We fit wall splits and ceiling cassettes for households and businesses right across the Klang Valley, in Kuala Lumpur and in Selangor. Ring +60178570744 with the room size, or the model you already have, and we will arrange a look at the wall.
Why fitting decides performance
Two identical units on two identical walls can cool very differently. The difference sits in four things. The capacity chosen for the room. The length and shape of the pipe run. The fall on the drain, and whether the air came out before the gas went in. Each is decided once, on fitting day, and each is expensive to revisit.
So the work starts at the wall, before anyone opens the box. Where the wall, the drain route or the circuit will not carry the unit you have picked, we say so at the site visit. You then get the option that does work.
What we fit
Ten of the jobs and decisions that come up on an install, and how each one is handled.
A room with no aircond needs its capacity worked out before anything is bought. We measure the floor area, count the glazing and note which wall takes the afternoon sun, then name the horsepower that suits it.
A room that never quite gets cold on a 1.0 HP unit usually carries more heat load than the unit was picked for. The fault is the sizing, not the machine, and an undersized system runs flat out and still loses.
A replacement goes back on the same wall in most cases, and the old pipework is tested before anyone reuses it. Copper that carried a burnt-out compressor holds acid and debris, so that run comes out.
A relocation is a full install with a recovery at the start. We pump the gas back into the outdoor unit, disconnect it, re-run the pipe and drain at the new position, then vacuum and recharge.
Condensate moves by gravity alone, so the drain line needs a continuous fall to the outlet. A dip anywhere along the run holds water, and that is where the smell and the overflow begin.
A condenser pushed into a tight recess re-breathes its own hot air and loses capacity on the days you need it most. We site it with clearance at the coil face and at the fan discharge.
A new unit needs a cable and a breaker rated for its starting current, with an isolator in reach of the outdoor unit. We check what is already there, because a shared socket circuit will trip.
The pipe, the drain and the cable travel together inside trunking, and the wall core is drilled with a fall to the outside. A kinked pipe restricts flow for the life of the unit.
Shops and offices usually need the work staged so the floor keeps trading. We fit in the order that suits your day and leave each unit running before starting the next.
Air and moisture left inside the pipework turn into acid and ice once the system runs. We evacuate the line with a vacuum pump and hold it, which also proves the joints before the charge is released.
Most of what decides a unit's performance is buried behind the trunking within a day of being done. That is why the list below matters more than the badge on the front cover.
Eight items make up the standard on every unit we fit, whether it goes into a bedroom or a shop floor.
How It Works
Four steps, and the quote comes after somebody has seen the wall.
Call or WhatsApp +60178570744 with the room size and, for a replacement, the model coming out. Photographs of the wall and the outdoor position often save a visit.
We look at the wall, the outdoor position, the drain route and the circuit. The quote covers the unit, the pipe run and the labour, and it holds unless the layout changes.
We sheet the room, core the wall, fix the bracket, run the pipe and drain inside trunking, and set the condenser on its feet or its bracket.
The system is evacuated, the charge released, and the unit run while we read the temperatures. You get the remote and a walk through the settings before we leave.
What you get
The standard every unit we fit is held to, and what you see before we go.
FAQ
Something here we have not covered? Ring +60178570744 and ask the technician who would be doing the job.
The size comes from the room. As a working guide, 1.0 HP suits a bedroom of roughly 100 to 120 square feet. A room with large windows or an afternoon-sun wall needs a step up. We measure before quoting.
The time depends on the pipe run and the outdoor position. A wall split beside an accessible balcony is quicker than a condenser going onto a first-floor bracket. We give you the window at the site visit.
Sometimes. Copper in good condition and of the right diameter can be reused once it has been flushed and pressure tested. Pipework that carried a burnt-out compressor holds acid and debris, and that run is replaced.
The vacuum pulls air and moisture out of the pipework. Moisture inside a refrigerant circuit forms acid and freezes at the expansion valve, and both shorten the life of the compressor.
Either works. Tell us the model you have in mind and we will confirm it suits the room. Give us the room instead and we will name the capacity to buy.
Most wall splits allow a pipe run of about 15 metres, and the manual for your model gives the exact limit. A run beyond the factory length needs extra refrigerant added to the charge.
The condenser needs clear air at the coil face and at the fan discharge. A recess, a boxed-in balcony or a position facing a close wall makes the unit re-breathe its own hot air and lose capacity.
Yes. The unit needs a cable and a breaker rated for its starting current, with an isolator within reach of the outdoor unit. A shared socket circuit trips once the compressor starts.
R32 is a single refrigerant and R410A is a blend of two. An R32 unit carries a smaller charge for the same cooling, and the two gases cannot be mixed or swapped in one system.
Yes, with the owner's permission for the wall core and the outdoor position. Management in most Kuala Lumpur condominiums also sets rules on where a condenser may sit, so check those before booking.
The wall is cored once, at the diameter the pipe set needs, and trunking covers the run. We sheet the floor and the furniture, and we clear the dust before leaving.
Yes. A cassette needs a ceiling void deep enough for the body and its drain pump, plus access for the pipe and drain runs. We check the void at the site visit before quoting.
More services
General servicing for a unit that is still running but no longer performing. We inspect, clean and correct what we find, then test it before we leave.
We handle:
Fast and reliable repair for all types of aircond issues. We diagnose problems and fix them correctly the first time.
We repair:
Improve air quality and efficiency with our deep cleaning service. We remove dust, dirt and bacteria.
We repair:
Regular maintenance keeps your aircond running at its best and helps prevent unexpected breakdowns.
We repair:
Low cooling? It might be low gas. We refill your aircond with the right gas for powerful cooling.
We repair:
From capacitor to wiring issues, we handle all electrical problems safely and professionally.
We repair:
Testimonials
Real feedback from our valued clients across Kuala Lumpur who trust Ad Aircond Solution for their cooling comfort.
Trusted by Homeowners & Businesses Across Kuala Lumpur
Your comfort is our priority. We’re proud to deliver service you can count on.
The team was professional, punctual, and very thorough. My aircond is now running perfectly cool. Highly recommended for anyone in KL.
Quick response and excellent repair service. The technician explained everything clearly and fixed the problem on the spot. Great job!
Smooth installation and very neat workmanship. The new system works fantastic and the place was left clean after the job.